Functional Details 
15 
 
Figure 6. Differential voltage example: common mode voltage of 11 V 
If you decrease the common-mode voltage to -7 V, the differential stays at ±8 V. However, the solution now 
violates the input range condition of -10 V to +20 V. The voltage on each analog input now swings from -3 V to 
-11 V. Voltages between -10 V and -3 V are resolved, but those below -10 V are clipped (see Figure 7). 
 
Figure 7. Differential voltage example: common mode voltage of -7 V 
Since the analog inputs are restricted to a −10 V to +20 V signal swing with respect to ground, all ranges except 
±20V can realize a linear output for any differential signal with zero common mode voltage and full scale signal 
inputs. The ±20 V range is the exception. You cannot put −20 V on CHHI and 0 V on CHLO since this violates 
the input range criteria. 
The table below shows some possible inputs and the expected results. 
Sample inputs and differential results 
CHHI 
CHLO 
Result 
-20 V 
0 V 
In Valid 
-15 V 
+5 V 
In Valid 
-10 V 
0 V 
-10 V 
-10 V 
+10 V 
-20 V 
0 V 
+10 V 
-10 V 
0 V 
+20 V 
-20 V 
+10 V 
-10 V 
+20 V 
+10 V 
0 V 
+10 V 
+15 V 
-5 V 
+20 V 
+20 V 
+20 V