Omron FQM1-CM001 ユーザーズマニュアル

ページ / 414
75
Wiring Servo Relay Units
Section 3-4
Applicable Connector-Terminal Block Conversion Units
Recommended Wire 
Size
The recommended size for cable wires is AWG24 to AWG26 (0.2 to
0.13 mm
2
). Use a cable with an outer diameter of less than 1.61 mm.
3-4
Wiring Servo Relay Units
XW2B-80J7-1A Servo Relay Units can be used to connect Motion Control
Modules and Servo Drivers.
A Servo Relay Unit simplifies wiring, e.g., from a Motion Control Module to
two Servo Drivers, for general-purpose I/O wiring, such as for switches and
sensors, and for RS-422A line wiring.
The Servo Relay Unit uses a special cable and simplifies connections from
one Motion Control Module to two Servo Drivers, such as the W Series and
SMARTSTEP Series.
Servo Relay Units can be mounted to DIN Track or on the panel itself.
Connecting Cable
Connector-Terminal Block 
Conversion Unit
Number of 
pins
Size
XW2Z-
@@@K
XW2D-40G6
40 pins
Miniature
XW2B-40G5
Standard
XW2B-40G4
Standard
XW2Z-
@@@J-A28
XW2D-34G6
34 pins
Miniature
IN
C
se
rvo1
AB
S _C
W
-
0
19