OmniWare Pro 12 ScanSoft ユーザーズマニュアル

ページ / 100
Chapter 4
Training
71
IntelliTrain remembers the training data it collects, and adds it to any 
manual training you have done. This training can be saved to a training 
file for future use with similar documents. 
Training files
If you want to be prompted to save your unsaved training data when you 
close the document, select that option in the Proofing panel of the 
Options dialog box. Unsaved training data is stored in an OmniPage 
Document. If you do not save the document as an OPD, unsaved 
training is discarded when the document is closed.
Saving training to file, loading, editing and unloading training files are all 
done in the Training Files dialog box. Open this from the Proofing panel 
of the Options dialog box or the Tools menu.
Unsaved training can be edited in the Edit Training dialog box, an 
asterisk is displayed in the title bar in place of a training file name. It 
remains unsaved when you close the Edit Training dialog box. Save it in 
the Training Files dialog box.
A training file can be also edited; its name appears in the title bar. If it has 
unsaved training added to it, an asterisk appears after its name. Both the 
unsaved and the modified training are saved when you close the dialog 
box.
The Edit Training dialog box displays frames containing a character 
shape and an OCR solution assigned to that shape. Click a frame to select 
it. Then you can delete it with the Delete key, or change the assignation. 
Use arrow keys to move to the next or previous frame.
Select this, click 
Save and type 
in a name to 
save a new 
training file.
Select this to 
unload a 
training file.
Click this to edit the 
selected training file
in the Edit Training 
dialog box.
Use this also to save new 
training into a loaded 
training file. It is listed as:
<File name>
 [modified]