NOTE:  When the Conservative Factor is set ON,
the No Deco Limit times are reduced to values
equivalent to those that would be available at
the next higher 3000 foot (915 meter) Altitude.
Refer to the tables on Pages 166/167.
SET BACKLIGHT DURATION information includes (Fig. 61):
>  Graphic GLO.
>  Symbol TIME.
>  Set Point, flashing.
  Pressing and releasing the S button momentarily (< 2
seconds each time) will step through the Set Points of 0, 5,
and 10 (:XX seconds).
  Pressing and releasing the A button momentarily (< 2
seconds) will save the setting and/or advance to the SET
SAMPLING RATE screen with the Set Point flashing.
  Pressing and releasing the A button momentarily and
repeatedly (< 2 seconds each time) will step through the
SET U screens.
  Depressing the A and S buttons simultaneously for 2
seconds will save the setting and revert back to the SET U
screen.
  Depressing and holding the M button for 2 seconds or if no
button is pressed for a period of 2 minutes operation will
revert to the NORM or GAUG SURF MAIN screen.
Fig. 61 - SET BACKLIGHT
DURATION
The Backlight will
not remain On for
the additional
Duration time set if
the L button is held
depressed longer
than 10 seconds.