TLBG (TISSUE LOADING BAR GRAPH) (Fig. 28a)
As your Depth and Elapsed Dive Time increase, the TLBG (Tissue
Loading Bar Graph) will add segments to represent the absorp-
tion of nitrogen.
While ascending to shallower depths, the number of segments
displayed will begin to recede, offering a graphic representation
of your multilevel diving capability.
O2BG (OXYGEN ACCUMULATION BAR GRAPH) (Fig. 28b)
If FO2 was set for a numerical value (Nitrox), the Oxygen
Accumulation Bar Graph (O2BG) will add segments to represent
oxygen accumulation for that dive, or 24 hour period, whichever
amount is greater.
VARI (VARIABLE ASCENT RATE INDICATOR) (Fig. 28c)
The Variable Ascent Rate Indicator (VARI) shows how fast you
are ascending.  When you exceed the maximum recommended
ascent rate for the depth you are at (see page 10), the TOO
FAST icon will appear flashing and all segments of the VARI will
flash (Fig. 29).  The flashing will stop and the TOO FAST icon
will be removed from the display when your Ascent Rate is
slowed below the alarm value.
Fig. 28 - BAR GRAPHS
Fig. 29 - ASCENT TOO FAST
a
c
b