Create Management Signature Keys
This test verifies that the unique signature keys used for information security were 
written to the Management Service database successfully. If this test failed, communi-
cation with the database host may have failed, the account settings used to connect 
may be incorrect or the installation may have failed to configure your server correctly.
Create Encryption Management Key
This test verifies that the unique encryption management key used for information 
security was written to the Distribution Service successfully. If this test failed, com-
munication with the Distribution Service host may have failed, or the installation may 
have failed to configure your server correctly.
Publish Management Data
This test publishes the schema and encryption management key to all users managed 
by this Management Service.
If there is a problem or error, the application exception will be logged. The most common issues 
preventing a successful installation are:
1. Certificate configuration. Verify that the certificate is trusted and valid. Ensure that the cer-
tificate is placed in a certificate store that the ASP.NET account has access to.
2. DNS or name resolution issues. Verify communication with the Distribution Server by open-
ing one of the following URLs:
(DS) http://machinename/policyserver/shieldclient.asmx (client)
Figure 105 : Distribution Service - Client Communication