138 Chapter 8 RMON
214393-A
 
To delete an alarm:
1
From the Device Manager main menu, choose RMON >Alarms.
Value
The value of the statistic during the last sampling period. For example, if the sample 
type is deltaValue, this value is the difference between the samples at the beginning 
and end of the period. If the sample type is absoluteValue, this value is the sampled 
value at the end of the period. This is the value that is compared with the rising and 
falling thresholds. The value during the current sampling period is not made available 
until the period is completed and remains available until the next period completes. 
StartupAlarm
The alarm that may be sent when this entry is first set to valid. If the first sample after 
this entry becomes valid is greater than or equal to the risingThreshold and 
alarmStartupAlarm is equal to risingAlarm(1) or risingOrFallingAlarm(3), then a single 
rising alarm is generated. If the first sample after this entry becomes valid is less than 
or equal to the fallingThreshold and alarmStartupAlarm is equal to fallingAlarm(2) or 
risingOrFallingAlarm(3), then a single falling alarm is generated.
RisingThreshold
A threshold for the sampled statistic. When the current sampled value is greater than or 
equal to this threshold, and the value at the last sampling interval was less than this 
threshold, a single event is generated. A single event is also generated if the first 
sample after this entry becomes valid is greater than or equal to this threshold and the 
associated alarmStartupAlarm is equal to risingAlarm(1) or risingOrFallingAlarm(3). 
After a rising event is generated, another such event is not generated until the sampled 
value falls below this threshold and reaches the alarmFallingThreshold.
RisingEventIndex
The index of the eventEntry that is used when a rising threshold is crossed. 
The eventEntry identified by a particular value of this index is the same as identified by 
the same value of the eventIndex object. If there is no corresponding entry in the 
eventTable, then no association exists. In particular, if this value is zero, no associated 
event is generated, because zero is not a valid event index. 
FallingThreshold
A threshold for the sampled statistic. When the current sampled value is less than or 
equal to this threshold, and the value at the last sampling interval was greater than this 
threshold, a single event is generated. A single event is also generated if the first 
sample after this entry becomes valid is less than or equal to this threshold and the 
associated alarmStartupAlarm is equal to fallingAlarm(2) or risingOrFallingAlarm(3). 
After a falling event is generated, another such event is not generated until the sampled 
value rises above this threshold and reaches the alarmRisingThreshold. 
FallingEventIndex
The index of the eventEntry that is used when a falling threshold is crossed. 
The eventEntry identified by a particular value of this index is the same as identified by 
the same value of the eventIndex object. If there is no corresponding entry in the 
eventTable, then no association exists. In particular, if this value is zero, no associated 
event is generated, because zero is not a valid event index. 
Owner
The network management system which created this entry. 
Status
The status of this alarm entry. 