Nortel Networks Circuit Card ユーザーズマニュアル

ページ / 908
 Overview
 Page 43 of 906
Figure 6
Call connection sequence – near-end station receiving call
553-AAA1113
High-
resistance
loop
Line card unit idle
(2-way voice
connection)
Remarks
Ground on tip/
battery on ring
Signal/direction
State
  System
Ground on tip/ 
battery on ring
High-resistance loop
Ground on tip/ 
battery on ring
Far-end station 
on hook
Near-end station 
on hook
If near-end station hangs up first, the 
following occurs: Line card detects drop 
in loop current. CPU removes timeslot 
assignments.
If far-end station hangs up first, the 
following occurs: The system detects 
disconnect signaling from trunk. CPU 
removes timeslot assignments. Person 
at near-end station recognizes end of 
call and hangs up. 
No battery current drawn.
Far-end station goes off hook and 
addresses (dials up) near-end station. 
The system receives the incoming 
call on a trunk and determines that the 
call is for a specific unit terminal number 
(TN) and  assigns message timeslots.
The system applies 20 Hz ringing to 
ring lead.
Ringing
Low-resistance loop
Near-end station 
off hook
Near-end station goes off hook.
Near-end 
station
The system detects increase in loop 
current, trips ringing, and cuts call 
through to near-end station.
Line card unit is ready for the next call.
High-
resistance 
loop
Line card unit is ready for the next call.
High-
resistance 
loop
Line card unit idle
Line card unit idle
High-resistance loop
Far-end 
station 
through 
PSTN
Alert