Nortech Systems Adept RS-232/TERM ユーザーズマニュアル
Configuring a Single sDIO
Adept SmartController User’s Guide, Rev. E
99
5. Type N at the following prompt.
Attached controller 0. Change this value?
Then, press ENTER to continue.
6. Type Y at the following prompt.
Digital input block: 16 Change this value?
Then, press ENTER to continue.
7. Enter a new value for the input block at the following prompt.
Enter new value:
Then, press ENTER to continue.
8. Type Y at the following prompt.
Digital output block: 16 Change this value?
Then, press ENTER to continue.
9. Enter a new value for the output block number at the following prompt.
Enter new value:
Then, press ENTER to continue.
10. Type Y at the final prompt.
Do you want to save these changes?
Then, press ENTER to continue.
After selecting block numbers, you must assign groups of signal numbers to each block.
NOTE: You must select a unique block number for the Inputs and Outputs
of each sDIO in your system. Repeat the procedure above for each sDIO.
of each sDIO in your system. Repeat the procedure above for each sDIO.
Assigning I/O Signal Numbers
The I/O signal number ranges are valid for the sDIO:
• Inputs 1033 to 1512
• Outputs 0033 to 0512
You will need to perform the follow steps to assign I/O signals to specific blocks, if you
choose a block other than 16.
choose a block other than 16.
1. Load and Execute the CONFIG_C.V2 utility.
2. Select option 2.
2 - V+ System Configuration Data
Then, press ENTER to continue.