SECTION VIII
 
TROUBLESHOOTING 
PROBLEM  
1. Sluggish heater 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
2. High Fuel 
Consumption 
 
 
 
 
 
 
 
 
3. Back puffing 
 
 
 
 
 
 
4.  Smoke rollout when 
heater door is opened 
 
 
   POSSIBLE CAUSE
 
1. Obstruction in chimney 
 
2. Improperly sealed trim kit 
or direct connect kit 
 
 
 
 
 
3.  Wet or unseasoned wood 
being burned. 
4.  Poor chimney draft 
 
 
 
 
1.  Improper regulation of 
draft or inlet air 
 
 
 
 
2.  Improper door fitting 
 
 
 
1. Gusts of Wind 
 
 
 
 
 
1.  Wind gusts blowing down 
the chimney 
 
 
 
2.  Opening heater door too 
fast 
 
        
SOLUTION  
 
1.  Check for and remove 
obstruction 
2.  (a)  Check trim kit gasketing 
seal to fireplace and gasket 
as necessary to seal unit.  
Gasket under front bottom of 
stove if needed.  (b)  Check 
seal if direct connect and 
correct 
3.  Burn dried natural seasoned 
hard wood 
4.  Improper chimney height or 
wrong size flue is being 
used.  Cooler temperatures 
caused by external chimney 
 
1.  Close inlet air control as 
much as possible to maintain 
desired heat output.  Check 
gaskets, reinstall fiberglass 
gasket around doors and 
glass as necessary 
2.  Check door gasket, check 
adjustment of door latch, 
check door hinges 
 
1.  Smoke shelf in chimney is 
filled with creosote & ash. 
Chimney may need wind 
diverter.  Raise chimney for 
better draft 
 
1.  Smoke shelf in chimney is 
filled with creosote & ash.  
Chimney may need wind 
diverter. Raise chimney for 
better draft 
2.  Open air control.  Crack door 
for 15 seconds before fully 
opening door 