CTR_Pulse
Format
status = CTR_Pulse (deviceNumber, ctr, timebase, delay, pulseWidth)
Purpose
Causes the specified counter to generate a specified pulse-programmable delay and pulse
width.
width.
Parameters
Input
Parameter Discussion
ctr is the counter number.
Range:
1, 2, or 5 for an MIO device except the E Series devices.
1 through 10 for a PC-TIO-10.
1 through 10 for a PC-TIO-10.
timebase selects the timebase, or resolution, to be used by the counter. timebase has the
following possible values:
following possible values:
–1:
Internal 5 MHz clock used as timebase (200 ns resolution) (AT-MIO-16F-5,
AT-MIO-64F-5, AT-MIO-16X, and PC-TIO-10 only).
AT-MIO-64F-5, AT-MIO-16X, and PC-TIO-10 only).
0:
TC signal of ctr-1 used as timebase.
1:
Internal 1 MHz clock used as timebase (1 µs resolution).
2:
Internal 100 kHz clock used as timebase (10 µs resolution).
3:
Internal 10 kHz clock used as timebase (100 µs resolution).
4:
Internal 1 kHz clock used as timebase (1 ms resolution).
5:
Internal 100 Hz clock used as timebase (10 ms resolution).
6:
SOURCE1 used as timebase if 1
≤
ctr
≤
5 or SOURCE 6 used as timebase
if 6
≤
ctr
≤
10.
7:
SOURCE2 used as timebase if 1
≤
ctr v 5 or SOURCE 7 used as timebase
if 6
≤
ctr
≤
10.
Name
Type
Description
deviceNumber
i16
assigned by configuration utility
ctr
i16
counter number
timebase
i16
timebase value
delay
u16
interval before the pulse
pulseWidth
u16