Kramer Electronics Home Theater Screen VP-747 ユーザーズマニュアル

ページ / 59
KRAMER:  SIMPLE CREATIVE TECHNOLOGY 
VP-747 Communication Protocol 
 
40 
11  VP-747 Communication Protocol 
This section includes the Communication Protocol for the VP-747
Communication Confirm: 
 
Send 
CR 
Reply 
CR> 
Set Command 
 
Send 
Y
Control_TypeFunctionParamCR 
Reply 
Z
Control_TypeFunctionParamCR> 
Get Command 
 
Send 
Y
Control_TypeFunctionCR 
Reply 
Z
Control_TypeFunctionParamCR> 
Example: set Preview Source Type of Current Channel = RGBHV 
 
Send 
Y
0430CR 
Reply 
Z
0430CR> 
Example: get Preview Source Type of Current Channel 
 
Send 
Y
143CR 
Reply 
Z
1430CR > 
: ASCII Code 0x20 
CR : Ascii Code 0x0D 
After set type Command setting, the system will respond with a string. 
Baud rate: 9600/115200bps, Data Bit: 8Bit, Parity: None, and Stop Bit: 1Bit.  
 defines the Set Commands: