Section 6 – Basic operations
06/97 – 1.00 – 6-1
6 – Basic operations
This section explains some of the basic operations 
using the DA-98. Section 8, “Advanced opera-
tions” d
escribes more advanced operations.
Most operations on a DA-98 are similar to those 
on a traditional analog multitrack recorder, but we 
suggest that you read this section and the next to 
learn about the features of the DA-98.
6.1 Formatting a tape
Before you use a tape in the DA-98, you must first 
format it. This marks internal synchronization pat-
terns for the servo to follow on subsequent passes 
through the tape as well as the subcode data 
(ABS). No audio data is normally recorded during 
a formatting operation (but see below).
While formatting is proceeding, you cannot per-
form any other transport operation except stop-
ping the tape.
You cannot change the sampling rate while for-
matting is in progress.
1) Switch on the DA-98 and load a tape into the 
tape loading slot [3]. As the tape is loaded and 
threaded, the tape counters will show 
.
For details of tapes that you can use in the DA-98, 
see 1.5, “Recommended tapes”.
2) Press REW [32] to take the tape to the 
beginning. When the beginning of the tape is 
reached, the tape counter will show 
 
(“beginning of tape”).
3) Press the 
FORMAT/Fs
 switch [6]. The 
FORMAT
 
indicator will start blinking. Press the 
FORMAT/
Fs
 switch again within 5 seconds. The 
FORMAT
 
indicator will then light steadily.
If you do not press the 
FORMAT/Fs
 switch twice 
within 5 seconds, the indicator will go out. This is 
a feature designed to stop you formatting a tape 
accidentally.
4) Now use the 
FORMAT/Fs
 switch to select the 
sampling frequency (either 44.1kHz or 48kHz).
The sampling frequency that you select depends 
on the eventual use for the recording. For audio 
work, selecting 44.1kHz will allow you to produce 
CD master tapes with no frequency conversion.
5) To start formatting the tape, hold down the 
RECORD
 key [36] and press the 
PLAY
6) The tape will format to the end, and then 
rewind automatically, stopping at the 
 position.
You are now able to use the tape for recording.
It is possible to format tapes on a number of 
DTRS units simultaneously. For details, see 9.4.1, 
“Synchronized formatting”.
6.1.1 Aborting the format process
To abort the process before formatting actually 
takes place (i.e. you have pressed the 
FORMAT/Fs
 
switch twice in error), press the 
CLEAR
 key [11]. 
The 
FORMAT
 indicator will go out.
As explained earlier, the only transport operation 
you can perform once formatting has started is to 
stop the tape. 
NOTE
If you do press the 
FORMAT/Fs
 switch twice so 
that 
the indicator lights steadily and you then change your 
mind about formatting the tape, you can use the 
CLEAR
cancel the operation.
NOTE
If a digital signal is received at the 
DIGITAL I/O
 
jack 
[45] as selected and shown by the 
DIGITAL IN
 
switch 
and indicator [15], the DA-98’s recording and playback 
sampling frequency is automatically determined by the 
sampling frequency of the input signal and you cannot 
change it.
NOTE
The tape counter may show a negative ABS time for a 
short while at the start of the formatting process. While 
it is displaying a negative value, no audio recording can 