Juniper Networks fi-6000NS ユーザーズマニュアル

ページ / 357
244
■  Failure to connect to a remote computer using its server 
name
If connection to a remote computer using a FQDN is not possible even after the server name has
been checked using a ping test, try the following steps:
6.3.3 Failure to cannot the Scanner using a Web Browser
If the "Login" screen does not appear after the scanner's URL is specified in the web browser, try
the following steps:
No.
Problem
Action
1
Check if a network connection is possible by 
trying the same solution for "Failure to 
connect to a remote computer using its IP 
address" (page 242).
2
The scanner's DNS server or WINS server 
settings are invalid.
Check that the DNS and WINS server settings 
are correct.
3
The DNS server or WINS server is not 
functioning normally, or there is an error with 
the DNS or WINS server network connection.
Ping the DNS and WINS servers to check they 
are functioning normally.
If the DNS or WINS server is not functioning, 
request the network administrator to check its 
status.
No.
Problem
Action
1
Check if a network connection is possible by 
trying the same solution for "Failure to 
connect to a remote computer using its IP 
address" (page 242).
2
The DNS server or WINS server is not 
functioning normally, or the scanner name has 
not been registered in the DHCP or WINS 
server.
For the URL in the web browser, use the 
following IP address to check the connection.
  Example:   http://192.168.1.200/
If it is possible to connect the scanner from the 
web with a specified IP address, specify the 
scanner's IP address in the DNS or WINS 
server. Also, check the DNS or WINS server 
settings on the web browser terminal.
3
A misconfigured firewall between the web 
browser and the scanner is denying access.
If there is a firewall between the computer 
running the web browser and the scanner, 
check that it settings are not preventing access.