John Deere models are designed to be used with an LP-Gas 
Cylinder equipped with the new QCC
®
- Quick Closing Coupling 
system. 
The QCC
®
- system incorporates new safety features required 
by the American National Standards Institute (ANSI) and the 
Canadian Standards Steering Committee. 
•  Gas will not flow until a positive connection has been  
made. 
•  A thermal element will shut off the flow of gas between  
40
°
 and 00
°
 F. 
•  When activated, a Flow Limiting Device will limit the   
flow of gas to 10 cubic feet per hour. 
lP-GaS CylIndeR
The lP-Gas Cylinder is not included with the Gas Grill. Be sure 
to purchase one with the QCC
®
 valve. This valve is recognized by 
the external threads on the inlet port of the valve. QCC
®
 equipped 
cylinders are available from your local hardware stores or LP-Gas 
dealer. (Fig. )
 
WaRnInG: any aTTeMPT TO COnneCT THe ReGulaTOR,  
 
 
By uSe Of adaPTeRS OR any OTHeR MeanS,  
 
 
TO  any  OTHeR  ValVe  COuld  ReSulT  In  
 
 
daMaGe,  fIRe  OR  InjuRy and  May  neGaTe  
 
 
THe  IMPORTanT SafeTy feaTuReS deSIGned  
 
 
InTO THe QCC
®
-1 SySTeM. 
SPECIFICATIONS:
.  All  LP-Gas  Cylinders  used  with  this  appliance  must  be 
constructed  and  marked  with  the  specifications  for  LP-
Gas  Cylinders  in  accordance  with  the  Canadian  Transport 
Commission (CTC) for use in Canada, or the U.S. Department 
of Transport (DOT) for use in the U.S.A. 
.  The LP-Gas Cylinder used for this appliance must not have a 
capacity larger than 0 Ib. (9 kg). Approximately 8” (46cm) 
high ” (cm) diameter.
.  All  LP-Gas  Cylinders  used  with  this  appliance  should  be 
inspected at every filling and re-qualified by a licensed service 
outlet at the expiry date (0 years), in accordance with the DOT 
(USA) and CTC (Canada) codes for LP-Gas Cylinders. 
4.  All LP-Gas Cylinders used with this appliance must be provided 
with a shut-off valve terminating in a cylinder valve outlet No. 
510, specified in the Standard for Compressed Gas Cylinder 
Valve Outlet and Inlet Connection (USA) ANSI/CGA-V-1-1977 
(Canada) CSA B96. 
 
The  cylinder  supply  system  must  be  arranged  for  vapor 
withdrawal. The cylinder must include a collar to protect the 
cylinder valve. The cylinder valve must include a safety relief 
device having direct communication with the vapor space of 
the cylinder.
Preparation
Fig.