Multi-Tech Systems MULTIVOIP MVP210/410/810 ユーザーズマニュアル

ページ / 144
Chapter 4: Configuring your VOIP 
Multi-Tech 
Systems, 
Inc. 
     
 
 
52 
DID Parameters 
The parameters applicable to the Direct Inward Dial (DID) telephony interface type are shown in the figure 
below and described in the table that follows.  The DID interface allows one phone line to direct incoming 
calls to any one of several extensions without a switchboard operator.  Of course, one DID line can 
handle only one call at a time.  The parameters described here pertain to the customer-premises side of 
the DID connection (DID-DPO, dial-pulse originating); the network side of the DID connection (DID-DPT, 
dial-pulse terminating) is not supported. 
The –SS and –FX models do not support DID. 
 
Figure 4-12: DID parameters 
DID Interface Parameter Definitions  
Field Name 
Values Description
Interface 
DID-DPO 
Enables the customer-premises side of DID functionality 
DID Options 
MultiVOIP’s use of DID applies only for incoming DID calls.  The Start 
Mode used by the MultiVOIP must match that used by the originating 
telephony equipment; else DID calls cannot be completed. 
Start Modes  
Immediate Start, 
Wink Start, 
Delay Dial 
 
For Immediate Start, the VOIP detects the off-hook condition initiated 
by the telco central-office call and becomes ready to receive dial digits 
immediately. 
For Wink Start, the VOIP detects the off-hook condition.  Then the 
VOIP reverses battery polarity for a specified time (140-290 ms; a 
“wink”) and then becomes ready to receive dial digits. 
For Delay Dial, the VOIP detects the off-hook condition.  Then the 
VOIP reverses battery polarity for a specified time (reverse polarity 
duration has wider acceptable range than for Wink Start) and then 
becomes ready to receive dial digits. 
Wink Timer 
(in ms) 
Integer values,  
in milliseconds 
This is the length of the wink for Wink Start and Delay Dial signaling 
modes. 
Applicable only when Start Mode parameter is set to “Wink Start” or 
“Delay Dial.” 
Dialing Options 
 
Inter Digit Timer 
Integer values, 
in seconds 
This is the length of time that the MultiVOIP will wait between digits.  
When the time expires, the MultiVOIP will look in the phonebook for 
the number entered.  
Default = 2. 
Message Waiting 
Indication 
-- 
Not applicable to DID-DPO interface.   
Inter-Digit 
Regeneration 
Timer 
Integer values, 
in milliseconds 
This parameter is applicable when digits are dialed onto a DID-DPO 
channel after the connection has been made.  The length of time 
between the outputting of DTMF digits. 