Moxa Technologies Industio CI-134 Series Industrial Serial Board RS-422 ユーザーズマニュアル

ページ / 79
Industio CI-134 Series User’s Manual  
2-1
2
2
 
Hardware Installation
The  installation  of  the 
Industio  CI-134  Series  consists  of  hardware  and  software
installation. The hardware installation is detailed in this chapter. The next chapter
deals with the software installation for various operating systems.
First Thing to Do: Interface Settings
1.  Before  installing  the  board  into  the  slot,  you  should  set  all  the  jumpers  and
switches to what you want.  The  default  (factor y)  settings  ar e  set  to  RS-485,
Auto Data Dir ection Contr ol mode, indicated as *
.
CAP Jumper JP1:
Open *
Not forcing the CAP address to 0xA700.
Shor t
Force the CAP address to 0xA700. Set to this if you want to do
quick har dwar e installation.
 Or forget the CAP address when
you want to re-configure the board with IO-IRQ.
Termination Resistor Jumper for Port 1
Industio CI-134 Series Board
Data Mode Switch
ON
ON
 1    2   3    4
CAP Jumper
JP1
ON
JP3
JP4
JP6
JP5
Interface Switch
Termination Resistor Jumper for Port 2
Termination Resistor Jumper for Port 4
Termination Resistor Jumper for Port 3
 1   2   3     4