There are 2 solutions to control RS-485 2-wire transmission.
Solution 1
The following model is common in RS-485 2-wire transmission.
sio_SetWr iteTimeouts(por t, 0);
/* Set sio_wr ite() into block mode if for
Windows NT and Windows 95/98 */
sio_RTS(por t, 1);
/*  Tur n  on  RTS  signal.  The  RS-485
por t is r eady for  tr ansmitting data. */
sio_wr ite(por t, buff, 10);
/* Wr ite 10 byte char acter s in " buff" .
The 
function 
blocks 
until 
last
char acter  tr ansmitted */
sio_RTS(por t, 0);
/*  Tur n  off  RTS  signal.  The  RS-485
por t is r eady for  r eceiving data. */
sio_r ead(por t, buff, 10); 
/* Read 10 bytes */
Solution 2
There  is  a  dedicated  RS-485  function  in 
PComm  or  API-232  library.  It
integrates the above functions of solution 1 regarding sending data as one.
sio_putb_x(por t, buff, tick ); /*
1. Tur n  on  RTS  and  r eady  for
tr ansmitting data.
2. Send data.
3. Wait for  tick time.
4. Tur n  off  RTS  and  r eady  for
r eceiving data. */
For more information on these functions, please refer to 
PComm library on-line Help