4.4.1 Monitoring a program
4 - 9
4.4 Monitoring Operations
1
OV
E
R
VI
EW
2
CRE
A
T
E
D
 PROGRAM 
AN
D SYS
TEM 
CONF
IGURA
TION
3
CR
EA
TI
NG PR
O
G
R
A
M
 IN
 
S
TRUC
TUR
E
D
 L
A
DDE
R/
FB
D
 LA
NG
UA
G
E
4
CREA
T
ING 
PROG
RAM IN ST 
LANGUAGE
5
CRE
A
TI
NG T
W
O OR 
MORE PROGRAM 
BLO
C
K
S
Monitor status
GX Works2 displays the Monitor status while it is executing the work window monitor.  
The Monitor status disappears when GX Works2 stops all types of monitoring.  
The Monitor status indicates the programmable controller CPU, simulator scan time, RUN/STOP status, etc.
Refer to the following manual for the Monitor status:
GX Works2 Version 1 Operating Manual (Common)
Monitor status display
● Switching of the current value display between decimal and hexadecimal
You can switch the current value display between decimal and hexadecimal using the following procedure.
Procedure to switch the current value display to decimal:
Select [Online] 
 [Monitor] 
 [Change Value Format(Decimal)].  
Procedure to switch the current value display to hexadecimal:
Select [Online] 
 [Monitor] 
 [Change Value Format(Hexadecimal)].  
Refer to the next page for the test operation.
Test operation
● Forcing a contact ON/OFF
Double-click a monitored device or label while pressing the 
 key to force a device in the programmable 
controller ON/OFF.  
● Changing the current value of a word device
Double-click a monitored word device to display the Modify Value screen where you can change the current value.
Select the Local Device monitor
Scan status
USER status
ERR. status
RUN/STOP status
Connection status
Input the numeric value to be set, and 
click the                button to change the 
current value to the input numeric value.