Programming Manual - Basic & Applied Instruction Edition
7 Basic Instruction
7.5 LDP, LDF, ANDP, ANDF, ORP, ORF
1
In
trodu
ct
ct
ion
2
O
ver
vi
ew
3
In
st
ru
ct
ion
Li
st
4
D
evices
in D
etail
etail
5
Specifi
ed t
he
he
D
evice &
C
onst
ant
ant
6
Bef
ore
ore
Pr
ogr
am
am
m
ing
7
B
asic
In
st
ru
ct
ion
8
FNC0
0-F
0-F
NC0
9
Pr
ogr
am
Flow
am
Flow
9
FN
C
C
10-FN
C
19
Mo
ve
ve
&
Co
mp
are
are
10
FNC2
0-F
0-F
NC2
9
Ar
ith.
&
&
Logic
O
per
ati
ati
on
7.5
LDP, LDF, ANDP, ANDF, ORP, ORF
Outline
LDP, ANDP, and ORP instructions for contacts detect the rising edge, and become active during one operation cycle
only at the rising edge of a specified bit device (that is, when the bit device turns ON from OFF).
Contact instructions LDF, ANDF and ORF detect the falling edge, and become active during one operation cycle only
at the falling edge of a specified bit device (that is, when the bit device turns OFF from ON).
only at the rising edge of a specified bit device (that is, when the bit device turns ON from OFF).
Contact instructions LDF, ANDF and ORF detect the falling edge, and become active during one operation cycle only
at the falling edge of a specified bit device (that is, when the bit device turns OFF from ON).
1. Instruction format
→ For the number of instruction steps, refer to Section 7.15.
2. Applicable devices
S: This function is supported only in FX
3U
/FX
3UC
PLCs.
Instruc-
tion
Bit Devices
Word Devices
Others
System User
Digit Specification
System User
Special
Unit
Index
Con-
stant
stant
Real
Number
Charac-
ter String
Pointer
X Y M T C S D
.b KnX KnY KnM KnS T C D R U
\G
V Z Modify K H
E
"
"
P
LDP
3 3 3 3 3 3
S
LDF
3 3 3 3 3 3
S
ANDP 3 3 3 3 3 3
S
ANDF
3 3 3 3 3 3
S
ORP
3 3 3 3 3 3
S
ORF
3 3 3 3 3 3
S
LDP
Load Pulse
Basic Instruction
LDP
−
Continuous
Operation
Pulse (Single)
Pulse (Single)
Operation
Mnemonic
Operation Condition
LDF
Load Falling Pulse
Basic Instruction
LDF
−
Continuous
Operation
Pulse (Single)
Pulse (Single)
Operation
Mnemonic
Operation Condition
ANDP
AND Pulse
Basic Instruction
ANDP
−
Continuous
Operation
Pulse (Single)
Pulse (Single)
Operation
Mnemonic
Operation Condition
ANDF
AND Falling Pulse
Basic Instruction
ANDF
−
Continuous
Operation
Pulse (Single)
Pulse (Single)
Operation
Mnemonic
Operation Condition
ORP
OR Pulse
Basic Instruction
ORP
−
Continuous
Operation
Pulse (Single)
Pulse (Single)
Operation
Mnemonic
Operation Condition
ORF
OR Falling Pulse
Basic Instruction
ORF
−
Continuous
Operation
Pulse (Single)
Pulse (Single)
Operation
Mnemonic
Operation Condition