Model Code
Initial value: K3
Numeric data type: Decimal (K)
When the 2AD-BD is connected, model code "3" is stored in the corresponding special data register.
The following table shows the special data registers that store the model code:
The following table shows the special data registers that store the model code:
Use the special data registers above to check whether a 2AD-BD is connected or not.
1. Program Example
4.8
Basic Program Example
Create the following basic program example to read out analog conversion (A/D conversion) data.
The following program will set the 1st board to voltage input mode and channel 2 to current input mode, and
will store the converted A/D value of channel-1 data into D100 and that of channel-2 data into D101.
The following program will set the 1st board to voltage input mode and channel 2 to current input mode, and
will store the converted A/D value of channel-1 data into D100 and that of channel-2 data into D101.
Even if the input data is not stored into D100 or D101, the data registers D8260 or D8261 can be directly used
in the timer/counter setting value or in a PID instruction.
in the timer/counter setting value or in a PID instruction.
Special data register
Description
1st board
2nd board
D8269
D8279
Model code
Checks the model code of the 1st
analog board
analog board
FNC224
LD =
D8269
K3
Y007
M8001
Normally
ON
ON
Normally
OFF
OFF
M8260
M8000
M8000
M8261
Sets the input mode of the 1st board
to the voltage input mode
(0 V to 10 V).
to the voltage input mode
(0 V to 10 V).
Sets the input mode of the 2nd board
to the current input mode
(4 mA to 20 mA).
to the current input mode
(4 mA to 20 mA).
M8002
Initial
pulse
pulse
RST
M6
RST
M7
Error status: b6 = OFF
Error status: b7 = OFF
M8000
FNC 12
MOV
K5
D8264
FNC 12
MOV
K5
D8265
Sets the averaging time to "5"
for channel-1 data.
for channel-1 data.
Sets the averaging time to "5"
for channel-2 data.
for channel-2 data.
M8000
FNC 12
MOV
D8260
D100
FNC 12
MOV
D8261
D101
Stores the A/D converted
channel-1 digital data into D100.
channel-1 digital data into D100.
Stores the A/D converted
channel-2 digital data into D101.
channel-2 digital data into D101.
FNC 12
MOV
MOV
D8268
K4M0
D8268
K4M0
FNC 12
MOV
MOV