Meridian Data Excel / Meridian Data Computer Drive 1 ユーザーズマニュアル

ページ / 139
100
 
 
E
XCEL 
M
ERIDIAN 
D
ATA
 
RAID 0 
• 
 
 
• 
RAID 1 
RAID 50 
• 
• 
 
 
RAID 10 
• 
 
 
 
RAID 5 
• 
• 
 
 
RAID 1E 
• 
 
 
 
RAID 0 
• 
• 
 
• 
RAID 0 
RAID 50 
• 
 
• 
 
RAID 10 
• 
 
• 
 
RAID 5 
 
 
• 
 
RAID 1E 
• 
 
• 
 
RAID 1 
 
 
• 
 
* Decreases the existing redundancy 
 
 
Important 
• 
The Target disk array may require more disk drives than the 
Source disk array 
• 
If the Target disk array requires an EVEN number of disk 
drives but the Source disk array has an ODD number, ADD a 
disk drive as part of the migration process 
• 
You cannot reduce the number of disk drives in your disk 
array, even if the Target disk array requires fewer disk drives 
than the Source disk array 
• 
RAID 1 (mirroring) works with two drives only. Only a single-
drive RAID 0 disk array or a single-drive JBOD can migrate 
to RAID 1. Other RAID Levels use too many drives to 
migrate 
• 
You cannot migrate a disk array when it is Critical or 
performing activities such as Synchronizing, Rebuilding, and 
PDM 
• 
You cannot migrate to RAID 6 or RAID 60. You cannot 
migrate from RAID 60 to another RAID level. You must 
create a new disk array and move your data to it 
 
 
Media Patrol 
Media Patrol is a routine maintenance procedure that checks the magnetic media on each disk drive. Media 
Patrol checks all physical drives assigned to disk arrays. Media Patrol does not check unconfigured drives. 
Media Patrol will also check spare drives, if those drives have Media Patrol enabled. Media Patrol for spare 
drives is enabled by default.  
Unlike Synchronization and Redundancy Check, Media Patrol is concerned with the condition of the media itself, 
not the data recorded on the media. If Media Patrol encounters a critical error, it triggers PDM if PDM is enabled. 
You can run Media Patrol from the subsystem.