Reported Event 
Corrective Action 
Blowers 
Blowers have started 
Normal. 
Blowers have stopped 
Verify that the cooling unit is properly installed. If the 
blower still does not turn, replace the blowers.  
Blower speed is 
increased 
Check the Astra ES for overheating.  
Blower speed is 
decreased 
Temporary overheat condition was corrected. 
Blowers are NOT 
functioning 
Replace the blowers. 
Blowers have been 
inserted 
Normal. 
Blowers have been 
removed 
Reinstall the cooling unit(s). If the blowers do not 
turn, replace the blowers. 
Blowers are functioning 
normally 
Normal. 
Blowers are NOT 
installed 
Reinstall the cooling unit(s). If the blowers do not 
turn, replace the blowers. 
Blower status is unknown  Check for airflow out of the cooling unit. If there is 
none, check for proper installation. 
(Blowers Events) 
 
 
 
Reported Event 
Corrective Action 
Cache 
BBU flushing has started  Astra ES cache is being flushed. 
BBU flushing has ended 
Astra ES cache has been flushed. 
BBU flushing has failed 
Astra ES cache could not be flushed. Check your 
cache flush interval setting.  
(Cache Events)