Reported Event
Corrective Action
Blowers
Blowers have started
Normal.
Blowers have stopped
Verify that the cooling unit is properly installed. If the
blower still does not turn, replace the blowers.
blower still does not turn, replace the blowers.
Blower speed is
increased
increased
Check the Astra ES for overheating.
Blower speed is
decreased
decreased
Temporary overheat condition was corrected.
Blowers are NOT
functioning
functioning
Replace the blowers.
Blowers have been
inserted
inserted
Normal.
Blowers have been
removed
removed
Reinstall the cooling unit(s). If the blowers do not
turn, replace the blowers.
turn, replace the blowers.
Blowers are functioning
normally
normally
Normal.
Blowers are NOT
installed
installed
Reinstall the cooling unit(s). If the blowers do not
turn, replace the blowers.
turn, replace the blowers.
Blower status is unknown Check for airflow out of the cooling unit. If there is
none, check for proper installation.
(Blowers Events)
Reported Event
Corrective Action
Cache
BBU flushing has started Astra ES cache is being flushed.
BBU flushing has ended
Astra ES cache has been flushed.
BBU flushing has failed
Astra ES cache could not be flushed. Check your
cache flush interval setting.
cache flush interval setting.
(Cache Events)