Meridian Data Excel / Meridian Data Computer Drive 1 ユーザーズマニュアル

ページ / 139
S
ECUR
S
TOR 
A
STRA 
ES      
                        
        
67
 
 
Caution 
When you initialize a logical drive, all the data the logical drive will 
be lost. Backup any important data before you initialize a logical 
drive. 
 
Initialize a Logical Drive: 
1.  Click the Subsystem 
 icon in Tree View.  
2.  Click the Logical Drive Summary 
 icon.  
3.  Click the   icon of the logical drive you want to Initialize.  
You can also start Initialization from the Subsystem 
 icon Background Activities tab 
4.  Click the Background Activities tab in Management View.  
5.  From the Background Activities dropdown menu, select Initialization.  
6.  To select Quick Initialization, check the box. 
If you checked the box, enter a value in the Quick Initialization Size field. This value is the size of the 
initialization blocks in MB.  
7.  If you did not select Quick Initialization, enter a hexidecimal value in the Initialization Pattern in Hex field or 
use the default 00000000 value.  
8.  Click the Submit button.  
9.  In the confirmation box, type the word confirm in the field provided.  
10.  Click the OK button.  
To view the progress of the Initialization, click the Background Activity tab. 
Running Redundancy Check 
Redundancy Check is a routine maintenance procedure for fault-tolerant logical drives (those with redundancy) 
that ensures all the data matches exactly. Redundancy Check can also correct inconsistencies. You can also 
schedule a Redundancy Check.  
Redundancy Check a Logical Drive: 
1.  Click the Subsystem 
 icon in Tree View.  
2.  Click the Logical Drive Summary 
 icon.  
3.  Click the   icon of the logical drive you want to Initialize.  
You can also start Redundancy check from the Subsystem 
 icon Background Activities tab 
4.  From the dropdown menu on the Background Activities tab, select Redundancy Check.  
5.  To select Auto Fix, check the box. 
This feature attempts to repair the problem when it finds an error.  
6.  To select Pause On Error, check the box. 
This feature stops the process when it finds an error. 
If Auto Fix is also checked, the process stops only when it finds a non-repairable error.  
7.  Click the Submit button.  
To view the progress of the Redundancy Check, click the Background Activity tab. 
Viewing the Logical Drive Check Table 
The Logical Drive Check Table displays errors related to a logical drive. Use this information to evaluate the 
integrity of the logical drive and to determine whether corrective action is needed. To View the tables:  
1.  Click the Subsystem 
 icon in Tree View.  
2.  Click the Disk Arrays 
 icon.  
3.  Click the Disk Array 
 icon.