47
 
11921 Slauson 
A
ve.  Santa Fe Springs, CA.  90670  (800) 227-41
16  F
AX (888) 771-7713
PUSH IBRS
AGAINST LOCK
4. Push the inboard rollstop back 
against the lock as if a wheel-
chair is pushing on the rollstop 
FIG. 47-1).
5. On the inboard rollstop switch, 
loosen screws (1) and (2) one-half 
turn (FIG. 47-2B). Next, rotate 
switch bracket clockwise until the 
switch activates with an audible 
“click”. Then tighten screws (1) 
and (2) securely.
6. Turn ON power switch on pump 
cover (FIG. 47-2A). Then raise 
(UP) the platform to fl oor level 
(FIG. 46-1). Verify that “INBD 
SW”
 is not displayed on the lift 
controller. If necessary repeat 
this procedure.
PLATFORM BELOW FLOOR LEVEL, 
WITH IBRS UP (LH SIDE SHOWN)
FIG. 47-1
PLATFORM BELOW FLOOR LEVEL, 
WITH IBRS UP (LH SIDE SHOWN)
FIG. 47-2A
CUT-AWAY VIEW OF 
LH VERTICAL ARM 
& IBRS SWITCH
FIG. 47-2B
SCREW (2)
SWITCH
(REF)
SCREW (1)
SWITCH
BRACKET
IBRS
POWER SWITCH