Maretron TLM150 ユーザーズマニュアル

ページ / 21
 
TLM150 User’s Manual  
 
 
 
 
 
Page 2  
 
Revision 1.2 
1.5  TLM150 Accessories 
Maretron offers the following accessories for the TLM150: 
 
•  TA-5H-1.5NPT 
1.5” NPT Displacement Hull Tank Adapter 
•  TA-5H-1.25BSP 
1.25” BSP Displacement Hull Tank Adapter 
•  TFT-5H 
 
SAE 5-Bolt Pattern Non-Displacement Hull Focus Tube 
•  TFT-1.5NPT   
1.5” NPT Non-Displacement Hull Focus Tube 
•  TFT-1.25BSP 
1.25” BSP Non-Displacement Hull Focus Tube 
 
1.6  Quick Install 
Installing the Maretron TLM150 involves the following steps. Please refer to the individual 
sections for additional details. 
 
1.  Unpack the Box (Section 2.1
2.  Choose a Mounting Location (Section 0) 
3.  Mount the TLM150 (Section 2.4) 
4.  Connect the TLM150 (Section 2.5
5. Configure or Program the Tank Number (Section 3.1) 
6.  Configure or Program Tank Capacity (Section 3.2
7.  Configure for Tank Depth and Shape 
o
 Configure 
or 
Program 
o
  Custom Calibration (Section 3.3.2) 
 
2  Installation 
2.1  Unpacking the Box 
When unpacking the box containing the Maretron TLM150, you should find the following items: 
 
•  1 – TLM150 Tank Level Monitor 
•  1 – TLM150 Gasket 
•  1 – TLM150 User’s Manual 
•  1 – Warranty Registration Card 
 
If any of these items are missing or damaged, please contact Maretron. 
 
 
2.2  Theory of Operation 
The TLM150 operates by directing a pulse of ultrasonic sound from the sensor component at 
the top of the tank down to the surface of the liquid in the tank. The TLM150 then measures 
the time it takes this pulse to travel down to the surface of the liquid, be reflected back up, and 
then be received back at the sensor component. Using the speed of sound, it uses this time to 
calculate the distance between the face of the sensor component and the surface of the liquid 
(or the tank bottom if the tank is empty). The cone width of the beam transmitted by the