LUCE PT-L6510E ユーザーズマニュアル

ページ / 50
35
ENGLISH
 LAMP SELECT
“LAMP SELECT” is used to choose from Single Lamp
and Dual Lamp modes depending on user's needs
or viewing conditions. In Single Lamp mode, the
projector may automatically select either lamp from
the 2 lamps, or the particular lamp can be specified.
DUAL:  Two lamps are used simultaneously.
SINGLE:  One of either lamps is used (lamp with
shorter operating hours is automatically selected).
SINGLE 1:  Lamp Unit 1 is always used.
SINGLE 2:  Lamp Unit 2 is always used.
OPTION 2 settings
1. Obtain the MENU window and select
(highlight) the desired adjustment item
with the 
 or 
 buttons (on the projector
or remote control).
2. Adjust the parameter value for the
selected item with the 
 or 
 buttons.
 LAMP POWER
“LAMP POWER” is used to change the luminance of
the projection lamp depending on user's needs or the
viewing conditions.
HIGH: Choose if a higher picture brightness is required.
STANDARD: Choose for normal picture brightness.
 LAMP RUNTIME
“LAMP RUNTIME” is used to cheque the cumulative
operating hours of the two projection lamps.
“1”:  Lamp 1 operating hours is displayed.
“2”:  Lamp 2 operating hours is displayed.
Caution
• Lamp can be selected without turning off the
projector.
•  If lamp mode is switched from “SINGLE”,
“SINGLE 1”, or “SINGLE 2” into “DUAL”, be sure
to temporarily turn the projector OFF, then turn it
ON again. The “DUAL” mode will become valid
only after the projector is turned back ON.
Note
• When the currently active lamp exceeds 2000 hours of
cumulative operating time, if in “SINGLE 1” or “SINGLE
2” mode, the other lamp takes over, provided that the
cumulative operating time of that lamp does not exceed
2000 hours.If the cumulative operating time of the other
lamp also exceeds 2000 hours when in “DUAL”,
“SINGLE”, “SINGLE 1”, or “SINGLE 2” mode, the
projector will enter Standby mode after 10 minutes.
• If only one lamp is installed in the projector, set lamp
mode to either “SINGLE 1” or “SINGLE 2”. “SINGLE 1”
or “SINGLE 2” is selected. If the corresponding lamp is
not installed, the other lamp will turn on. The same holds
for “SINGLE 2” mode. If “SINGLE” mode is selected, it
may take approx. 90 seconds before the lamp turns
ON.
 SETTING FUNCTION 1 [FUNC 1]
FUNCTION 1 is used to specify the function of the remote
control / “FUNC1” button. (“FUNC1” button functions differ
between the PT-L6510E and PT-L6600E.)
• PT-L6510E
• PT-L6600E
INDEX: Pressing the “FUNC1” button displays both
still and motion images on a split screen
(same as the “INDEX WINDOW” option in
the MAIN MENU).
MUTE: Pressing the “FUNC1” button mutes the sound
output.
STANDARD: Pressing the “FUNC1” button resets all
the parameter values now in the menu
t o   t h e   f a c t o r y   d e f a u l t ,   w i t h   a
“STANDARD” indicator shown in the
upper right corner of the menu.
Note
• If the cumulative operating hours exceeds 1800
hours, the hour indicator flashes in red.
OPTION 2
LAMP POWER
LAMP SELECT
FUNCTION 1
SET ID
LAMP RUNTIME
USER MODE
HIGH
MUTE
DUAL
 
7 H
1
ALL
SELECT
ADJ
ESC
FUNCTION 1
INDEX
MUTE
STANDARD
FUNCTION 1
MUTE
STANDARD
LAMP POWER
HIGH
STANDARD
LAMP RUNTIME
11 H
11 H
1
2
LAMP SELECT
DUAL
SINGLE
SINGLE 1
SINGLE 2
Note
• If it is not necessary for picture brightness to be very
high (in a small meeting room, etc.), it is advisable
that you set BRIGHTNESS to “STANDARD”. This will
save power consumption and extend lamp life.
* Press and hold the “ENTER”
button for approximately 3
seconds. (lamp with longer
operating hours is turned
off)