LUCE PT-L6510E ユーザーズマニュアル

ページ / 50
40
Indication of lamp monitor
This projector is equipped with 3 indicators to show when a lamp needs replacement or there is an abnormal
internal temperature. These lamps flash or light up to indicate a problem.
Turn the power off and follow the steps below.
RE
MO
TE
RG
B O
UT
OU
T
WI
RE
D
IN
IN
OU
T
IN
R/R
-Y/
PR
G/Y
SY
NC
/HD
VD
B/B
-Y/
PB
IN
OU
T
OU
T
IN
R
L
US
B
SE
RIA
L
S-V
IDE
O I
N
AU
DIO
 IN
RG
B
AU
DIO
AU
DIO
VID
EO
RG
B 2
 IN
OU
T
IN
DV
I-D
RG
B 1
 IN
> P
C <
TB
MU
15
2
Lamp 1 monitor (LAMP 1)
Lamp 2 monitor (LAMP 2)
Temperature monitor (TEMP) indicator
(Rear view of projector)
STAND BY (R)    LAMP1     LAMP2       TEMP
      ON (G)
• Is something 
blocking the vent?
• Has the projector 
been operating in a 
hot location?
• Is the air filter 
clogged?
Is replace lamp 
displayed on the 
screen when the 
power is turned on?
Are you turning the 
power back on 
immediately after it has 
been turned off?
There is a 
malfunction in the 
lamp circuit 
• Remove the object blocking the 
vent.
• Use the projector only in an 
environment having a temperature of 
°
C to 40 
°
C and humidity of 20% to 
80% (with no condensation).
• Turn the power off by following the 
steps on page 23 and clean the air 
filter. (See page 41) 
Lights when lamp runtime exceeds 
1800 hours. Have your dealer 
replace the lamp unit.
Wait until the light source lamp cools 
off before turning the power back on.
Turn the power off by following the 
steps on page 23 and consult your 
dealer.
Red lamp 
flasing
 (lamp unit lit)
 (PT-L6510E)
Temperature 
monitor 
TEMP
Red lamp lit
(lamp unit lit)
Red lamp lit
 (Lamp unit 
not lit)
 (PT-L6600E)
The ambient 
temperature or internal 
temperature is high.
Red lamp 
flashing
 (lamp unit 
not lit)
The lamp unit 
automatically shuts off 
(switches to standby 
state) due to abnormally 
high ambient 
temperature or internal 
temperature.
The inside is at an 
abnormally high 
temperature, or there 
are sudden 
temperature changes.
The lamp unit has 
automatically turned 
off (standby mode) 
because of a high 
temperature or 
sudden rise in 
internal temperature. 
It is time to replace 
the lamp unit.
Detected the Lamp 
curcuit abnormal 
condition.
Red lamp lit
Red lamp 
flashing
Lamp monitor  
LAMP1      LAMP2
Indicator
Display
Condition
Check
Measures
Caution
• To solve any problems that the TEMP and LAMP monitor show, first turn the power off by following the steps
on page 23.
• If the main power turns off after the TEMP monitor flashes, the projector has malfunctioned. Please consult
your dealer.