The following tables show the maximum number of 
units,  which  can  be  connected  to  the  two  outputs 
(A1 or A2) on a CU 6005 Central Unit in total or to 
each  of  the  four  outputs  (A1,  A2,  B1  or  B2)  on  a 
CU  6010  Central  Unit  or  to  each  output  on  an  EX 
6010 Extension Unit or to the output of a PS 6000 
Power Supply. 
 
Length of Feeding Cable 
Type CAT5 AWG24  
Length of inter connecting 
Cable, Type CAT5 AWG24  
Total cable length 
Max. number of  
CM/DM 60x0 pr output 
10 m 
1 m 
39 m 
30 
30 m 
1 m 
56 m 
27 
50 m 
1 m 
73 m 
24 
100 m 
1 m 
115 m 
16 
150 m 
1 m 
160 m 
11 
10 m 
2 m 
64 m 
28 
30 m 
2 m 
78 m 
25 
50 m 
2 m 
94 m 
23 
100 m 
2 m 
130 m 
16 
150 m 
2 m 
170 m 
11 
CM/DM 6560F Chairman/Delegate Units  
Length of Feeding Cable 
Type CAT5 AWG24  
Length of inter-connecting 
Cable, Type CAT5 AWG24  
Total cable length 
Max. number of CM/DM 
60x0   pr output 
10 m 
1 m 
35 m 
27 
30 m 
1 m 
53 m 
24 
50 m 
1 m 
70 m 
21 
100 m 
1 m 
113 m 
14 
150 m 
1 m 
159 m 
10 
10 m 
2 m 
58 m 
25 
30 m 
2 m 
72 m 
22 
50 m 
2 m 
88 m 
20 
100 m 
2 m 
126 m 
14 
150 m 
2 m 
166 m