Low Profile – 1600-000-A Advantage Series Service Manual – Domestic
 
SEQUENCE OF OPERATIONS / 1600-000-A, 1601-000-A 
 
MODEL 1600-000-A / 120 VAC / 60 HZ / NATURAL GAS 
MODEL 1601-000-A / 120 VAC / 60 HZ / L.P. GAS 
 
POWER SUPPLY 
Electrical power to be supplied to the oven by a three conductor cordset. Voltage from 
the black conductor to the white conductor to be 120 VAC.  
White conductor is Neutral. 
Green conductor is Ground. 
CONTROL BOX 
AUTO COOL DOWN 
When the temperature in either one of the Control Boxes reaches 120°F ± 3°F (49°C 
± 1.7°C), the Cooling Fan Thermostats will switch power to the Cooling Fans. The 
thermostats will interrupt power to the Cooling Fans when the temperature falls to 
100°F ± 3°F (37°C ± 1.7°C). 
MAIN FAN CIRCUIT 
120 VAC is permanently supplied to the normally open double pole power switch, a 
normally open contact of the oven power relay and the normally open cooling fan 
thermostats.  Closing the power switch supplies 120 VAC, through the 3 A cooling fan 
fuse, through both control box hi-limit thermostats to the coil of the oven power relay.  
These normally open contacts now close supplying 120 VAC, through the 10A main 
fan fuse to the 2 main fan motors and the 2 burner motors.  Power is also supplied to 
the cooling fans, the heat and conveyor control systems. 
BURNER CIRCUIT 
Closing the Oven Power Relay supplies 120 VAC to the (2) burner Systems 
NOTE: This oven utilizes (2) complete Burner/Temp. Control systems. The sequence 
of operations is the same for each system.120 VAC is supplied, through the 
Centrifugal Switch of the Main Fan Motor (this switch closes when the Main Fan 
reaches approximately 1600 R.P.M.) through the 10 Amp Fuse, to the Ignition 
Control, the Electronic Temperature Control, and the burner transformer.  As the 
Burner Blower reaches approximately 1600 R.P.M., its internal centrifugal switch will 
close, supplying 24 VAC to the ignition control. The Ignition Control operates on both 
24 VAC and 120 VAC.  When the control is energized by 24 VAC, 120 VAC is 
switched to the Hot Surface Igniter for 45 seconds for Hot Surface Igniter warm up.  
The igniter glows red, 24 VAC is switched to the gas valve which opens, and ignition 
should now occur.  If ignition does not occur in 6 seconds, the control will lock out.  To 
recycle after lockout, turn off the burner switch for 45 seconds and then turn the 
switch back on. 
TEMPERATURE 
CONTROL 
When the Centrifugal Switch of the Main Fan Motor closes, power is applied to the 
Temperature Control. The1K ohm Temperature Pot is adjusted to desired 
temperature. Thermocouple will provide varying millivolts to the Temperature 
Controller. The Temperature Controller supplies 120 VAC to the solenoid valve at 
intermittent intervals to maintain desired temperature.  The heat lamp is energized 
with the solenoid valve. 
CONVEYOR DRIVE 
Closing the on/off switch supplies 120 VAC through the oven power relay to the motor 
control board. AC volts are converted to DC volts and are supplied to the conveyor 
motor at terminals A+ and A-.Adjustments of the speed control potentiometer will 
change resistance at terminals P1 and P2 varying the DC voltage to the motor.  The 
speed of the conveyor motor will increase or decrease as the DC voltage from the 
board increases or decreases respectively. 
NOTE: 
The conveyor control uses a sensor and magnet, mounted on the conveyor motor that 
senses the motor speed.  Any change in motor load, (±RPM) is detected by the 
sensor and the voltage to the motor is adjusted accordingly. 
TEMPERATURE 
DISPLAY 
Closing the switch supplies 120 VAC to the primary of the temperature display 
transformer.  The secondary of this transformer supplies 12 VAC to the temperature 
display.  The thermocouple supplies D.C. millivolts to the temperature display.  The 
display converts this millivolt reading to a temperature reading.