Lexicon 570 ユーザーズマニュアル

ページ / 70
49
www.remotepossibilities.com
COMMAND>OUT R
OUTPUT STATUS REPORT
====== ====== ======
Output #1    Manual OFF
Output #2    Manual OFF
Output #3    Manual OFF
Output #4    Manual OFF
Time:  08/03/96 06:59:26
„
  Output Control Operations
To manually turn an output on or off, type OUT O at the command prompt. The Messenger 570 system will
report the present value of the first input and permit you to toggle the value by pressing the space bar. Press
<ENTER> when the output is in the desired state. The Messenger 570 system will repeat the process with the
next output and continue doing so until all of the outputs have been accessed.
COMMAND>OUT O
TURN OUTPUTS ON OR OFF
==== ======= == == ===
Press SPACE to change, CR if OK
Output #1   OFF ON  OFF
Output #2   OFF ON
Output #3   OFF ON
Output #4   OFF ON
„
  Output Setup
Type OUT S at the command prompt to control the configuration parameters for each output. You will get a list
of all configurable outputs. Select the one you wish to configure and you will get a sub-menu of parameters for
that output.