Protocol
•    XON/XOFF (default)
     In  the  XON/XOFF  protocol,  data  fl ow control is achieved by 
using XON (DC1) and XOFF (DC3) characters. Message blocks 
are not required to be bracketed by the Start of Text (STX) and 
End of Text (ETX) characters. However, at power up or after a reset 
all characters except ENQ or VT will be ignored until an STX is 
detected. The message length in this protocol is unrestricted. That 
is, the printer processes information as it is being downloaded and 
stops when there is no more information.
     XON/XOFF protocol conforms to generally accepted industry 
standards. No end-of-message response is sent to the host other 
than XOFF. An XON will be sent on power up. 
          Since DC1 and DC3 are used for data fl ow control, the printer status 
characters are different than those of the Standard Protocol. If the 
host ignores the printer’s XOFF, the printer will resend an XOFF 
after receiving every 15 characters from the host.
     Condition Character
     Buffer already full 
GS
     Printhead raised 
US
     Ribbon fault 
US
     No label stock 
EM
     Buffer now full 
DC4
     Printhead hot 
SI
     Label at strip pin 
FS
     Label skipping 
DC2
     Printing 
DC2