Installing the Processor Air Duct
1. Observe the safety and ESD precautions at the beginning of this book. See "
“Safety 
Information”
2. Power down the server and unplug all peripheral devices and the AC power 
cable(s). 
3. Remove the server system cover. For instructions, see 
“Removing the System 
Cover”
.
4. Turn processor air duct over to reveal underside (see letter “A”).
5. If two processors are installed: remove air dam (see letter “B”) by sliding slotted 
holes off duct pins.
Notes: Do not remove the air dam if only one processor is installed.
Do not remove memory air deflector.
Figure 21. Removing the Processor 2 Air Dam (Optional - only if two 
processors are installed)
6. Place the processor air duct over the processor socket(s). See the figure below. The 
front edge of the air duct should contact the fan module. Use caution not to pinch or 
disengage cables that may be near or under the air duct. 
7. Install the server system cover. For instructions, see 
“Installing the System Cover”
8. Plug all peripheral devices and the AC power cable(s) into the server.