Testing Pen Calibration 
If your terminal is not correctly interpreting pen touches, use this test to adjust the pen 
calibration. This test is for the i6550 only. 
Display 
Action 
 
To access the extended menu, restart the terminal 
by pressing [1] + [CAN] + [OK]; while the terminal 
is starting up, access the extended menu by 
pressing the [1] and [3] keys simultaneously. 
Extended Menu 
Serialnum Inject 
System Config 
System Info 
Supervisor Menu 
Diagnostic Menu 
Press [ ], [Enter] to select Diagnostic Menu. 
Diagnostic Menu 
Display 
Keypad 
Beeper 
RS232 
Tailgate 
USB 
Mag Stripe Reader 
Smart Card Reader 
SAM 
Touch Screen 
Signature Capture 
Pen Calibration 
Press [ ], [Enter] to select Pen Calibration. 
Please remove hands/objects 
from around the display 
Calibration will start in 3 
seconds… 
 
 
Using the stylus, tap the four-box grid. The box 
moves around to the next corner; tap again. 
Repeat until you are notified if the test was 
successful. 
Calibrate Pen
Please tap box