HP XC System Software 3.2.1 ユーザーズマニュアル

ページ / 158
Figure 1-9 HP BladeSystem c3000 Enclosure Bay Locations (Rear View)
1
Interconnect bay #1
2
Fans
3
Interconnect bay #2
4
Enclosure/Onboard Administrator Link Module
5
Power Supplies
6
Interconnect bay #3
7
Interconnect bay #4
1
Enclosure Downlink port
2
Enclosure Uplink port
3
Onboard Administrator/Integrated Lights Out port
Specific HP XC Setup Guidelines
The following enclosure setup guidelines are specific to HP XC:
On every enclosure, an Ethernet interconnect module (either a switch or pass-through
module) is installed in interconnect bay #1 (see callout 1 in
) for the administration
network.
Hardware configurations that use Gigabit Ethernet as the interconnect can share with the
administration network in interconnect bay #1.
Systems that use InfiniBand as the interconnect require a double-wide InfiniBand interconnect
switch module installed in interconnect bays #3 and #4 (see callouts 6 and 7 in
).
Some systems might need an additional Ethernet interconnect module to support server
blades that require external connections. For more information about external connections,
see
.
1.2.3 HP BladeSystem c-Class Onboard Administrator
The Onboard Administrator is the management device for an enclosure, and at least one Onboard
Administrator is installed in every enclosure.
1.2 Server Blade Enclosure Components
27