HP RC3000 ユーザーズマニュアル

ページ / 143
RC3000 Antenna Controller 
Chapter 3 
Detailed Operation 
 
 100  
 
3.3.1.2.2 Elevation Calibration 
 
REF_V:1.69 OFF:  0.0        CONFIG-ELEV  
 DOWN:  0   UP: 90.0   SF:50.00 
 LOOK:1  
SET REFERENCE VOLTAGE <0.50 – 4.50>           
 
REF_V:  
SET REFERENCE VOLTAGE <0.50 - 4.50> 
The elev_zero_voltage defines the voltage present when the elevation axis is at its reference position .  
See the elevation zero voltage installation step. 
OFF: 
 
ELEVATION OFFSET <-25.0/+25.0 DEGREES> 
The elev_squint_factor configuration item corrects for discrepancies between the antenna's electrical and 
mechanical bore sight alignment.  The squint factor also compensates for errors in the attachment of the 
elevation position sensor.  The elevation squint factor is the difference between the antenna's theoretical 
and actual elevation pointing angle.  The value for this constant is determined during the elevation 
alignment calibration procedure (2.4.2).  The VALUE OF THIS CONSTANT MUST BE SET TO 0.0 
BEFORE THE ELEVATION CALIBRATION OCCURS.  The nominal value of this constant is 0.0.  
 
DOWN:  
 
SET DOWN LIMIT <0-90 DEGREES> 
UP: 
 
 
SET UP LIMIT <0-90 DEGREES> 
The down_elev_limit and up_elev_limit configuration items specify the valid elevation operating range in 
degrees.  If the LOCATE mode calculates a target elevation outside of this range, an elevation range 
error will be triggered. 
The spiral search algorithm (when based on pot-based movements) also uses these values to limit the 
area that may be searched. 
SF: 
 
 
SCALE FACTOR <30.00 – 60.00 mV/deg> 
The elev_scale_factor_mv_deg configuration item specifies the observed output of the elevation 
inclinometer. 
EL_LAT: 
 
ELEV LOOK CONFIGURATION <1>HIGH <0>LOW 
The elevation_lat_configuration item is used for mount types that have different feed boom configurations 
to achieve different elevation pointing angles.  The reported elevation angle will be offset by different 
values according to whether the high or low elevation configuration is specified.  Other elevation related 
items such as stow and deploy positions will also be affected.  NOTE: for mounts that have only one 
feed boom configuration, this configuration item may be set to either value with no consequence.