HP RC3000 ユーザーズマニュアル
RC3000 Antenna Controller
Chapter 3
Detailed Operation
89
3.2.2.8 Settings
The SETTINGS mode provides a way to change the operational characteristics of the RC3000 without
having to go to the configuration group of screens. It also provides a way to reset a drive error without
going to the DRIVE RESET maintenance screen.
having to go to the configuration group of screens. It also provides a way to reset a drive error without
going to the DRIVE RESET maintenance screen.
1-AUTOPEAK:OFF SETTINGS
2- AP SIG:SS1
<0>RESET DRIVE
<1-2>CHANGE SETTING <MODE>MENU
<0>RESET
DRIVE
This selection is only available if an azimuth, elevation or polarization drive error (jam or runaway) is
active. Selecting 0 will attempt to clear the error.
active. Selecting 0 will attempt to clear the error.
1-AUTOPEAK:
AUTOPEAK <0>DISABLE <1>ENABLE <2>+PEAK
AUTOPEAK <0>DISABLE <1>ENABLE <2>+PEAK
Selection 0 allows the user to disable the autopeak function (OFF).
Selection 1 allows the user to turn the basic autopeak function on (ON).
Selection 2 allows the user to enable the terminal peakup function (ON+) described in 3.2.2.3.5. NOTE:
Verify that the required conditions for terminal peakup as described in 3.2.2.3.5 are present before
selecting this option.
Verify that the required conditions for terminal peakup as described in 3.2.2.3.5 are present before
selecting this option.
2-AP SIG:
SIGNAL SOURCE <1>RF <2>SS1 <3>SS2
SIGNAL SOURCE <1>RF <2>SS1 <3>SS2
Selection 2 allows the user to change the signal source that will be used with the autopeak function.