6)  Disconnect the rinse pump motor wiring at the closed end connectors.
7)  Remove the nut from the fl exible tube at the rinse pump motor discharge outlet and 
the bolts securing the bracket to the unit base.
8)  Remove the band from the pipe joint of the booster tank discharge pipe behind the 
rinse pump motor and the fl exible tube at the rinse pump motor suction inlet. Pull the 
end of fl exible tube out of the booster tank discharge pipe.
Note:  Use a hand mirror for easy removal.
9)  Remove the rinse pump motor together with the bracket. Remove the band from the 
pipe joint of the rinse pump motor suction inlet pipe and fl exible tube to release the 
fl exible tube.
10)  Unscrew the bracket, and remove the rinse pump motor.
11)  To replace, reverse the above procedure.
Note:
1.  Be careful not to mix up the wire colors. Miswiring will cause reversal of the pump 
motor, resulting in improper operation.
2.  Cover the connections with the original plastic sheet cover and secure with a nylon 
tie. Make sure the connections are situated so that water and condensation cannot 
reach the connections. 
3.  Be sure to use new O-rings and gaskets. Be careful of the direction of the 
U-packing for the suction inlet pipe.
12)  Make a trial run, and check for water leaks.
Fan Motor
Booster Tank 
Drain Hose
Rinse Pump Motor
Flexible Tube
Discharge 
Outlet Nut
[JWE-2400CUA-L-25B]
* For JWE-2400CUA-R-25B, fan motor and rinse 
pump motor are located behind control box
Rinse Pump Motor
U-Packing
Sunction Inlet Pipe