GENERAL DESCRIPTION
The  HI 9124 and HI 9125 are state-of-the-art waterproof, heavy-
duty pH meters designed to provide laboratory results and accuracy
under harsh industrial conditions.
A large dual-level LCD, with clear indications related to the electrode
and instrument status, pH and temperature displayed simultaneously,
and user friendly graphic symbols during calibration.
The pH calibration procedure is automatic with 5 memorized buffers
(4.01, 6.86, 7.01, 9.18 and 10.01),  buffer recognition and
automatic temperature compensation.
The HI 9125 can be used with ORP (Oxidation Reduction Potential)
electrodes. mV measurements automatically change from 0.1 to 1 mV
resolution when the reading reaches 700 mV.
PRELIMINARY EXAMINATION
PRELIMINARY EXAMINATION
PRELIMINARY EXAMINATION
PRELIMINARY EXAMINATION
PRELIMINARY EXAMINATION
GENERAL DESCRIPTION
GENERAL DESCRIPTION
GENERAL DESCRIPTION
GENERAL DESCRIPTION
GENERAL DESCRIPTION
Remove the instrument from the packing material and examine it to
make sure that no damage has occurred during shipping.
If there is any damage, notify your dealer or the nearest Hanna
Customer Service Center.
Each meter is supplied with:
• HI 1230B combination double-junction, gel pH electrode
• HI 7662 stainless steel temperature probe with 1 m (3.3’’) cable
• pH 4.01 & pH 7.01 buffer solutions, 20 mL sachet
• 100 mL plastic beaker
• 4 x 1.2 AAA rechargeable batteries (inside the instrument)
• HI 710044 inductive recharger with power adapter
• Instruction manual
• Rugged carrying case
Note: Save all packing material until you are sure that the instrument
functions correctly. All defective items must be returned in the
original packing with the supplied accessories.
26
OTHER ACCESSORIES
HI 710044 Inductive recharger
HI 721317 Rugged carrying case
HI 740157 Plastic electrode refilling pipet (20 pcs)
HI 76405
Electrode holder
HI 7662
Temperature probe with 1 m (3.3') screened cable
HI 8427
pH and ORP electrode simulator with 1 m (3.3')
coaxial cable ending in female BNC connectors
HI 931001 pH and ORP electrode simulator with LCD and 1 m
(3.3') coaxial cable ending in female BNC connectors
HI 1413B
Glass-body, single junction, flat tip, Viscolene, non-refillable, combination
pH electrode. Use: surface measurement.
ORP ELECTRODES
HI 3131B
Glass-body, refillable, combination platinum ORP electrode.
Use: titration.
HI 3230B
Plastic-body (PEI), gel-filled, combination platinum ORP electrode.
Use: general purpose.
HI 4430B
Plastic-body (PEI), gel-filled, combination gold ORP electrode.
Use: general purpose.
Consult the Hanna General Catalog for a complete and wide selection
of electrodes.
110 mm
4.3"
12 mm
0.5"
HI 1413
150 mm
5.9"
12 mm
0.5"
"S" VERSION
HI 3131
120 mm
4.7"
12 mm
0.5"
HI 3230
"S" VERSION
120 mm
4.7"
12 mm
0.5"
HI 4430
"S" VERSION