4–20 mA Option
6.3 4–20 mA Option
The 4–20 mA option provides a current loop for controlling external devices 
such as a chart recorder or PC. Either one or both of the 4–20 mA outputs can 
be factory installed and are isolated from each other.
6.3.1 4–20 mA Connection
The interface has a 3-ft cable with a connector on one end, and a 10-ft cable 
with two open wire leads on the other. Insert the connector into the sampler 
receptacle labeled “Auxiliary”, located on the left side of the control housing. 
On the 10-ft cable, the wire with clear insulation is positive (+) and the wire 
with black insulation is negative (-). 
Rating:
Isolation Voltage: 
Between sampler and either 4–20 mA output: 2500 V ac
Between the two 4–20 mA outputs: 1500 V ac
Maximum Resistive Load: 600 ohm
Output Voltage: 24 V dc - no load
Cable Required
4–20 mA Interface Cable (Cat. No. 2924), 25 ft long, 4-pin connector on one 
end, tinned wire leads on the other end.
6.3.2 4–20 mA Programming
1.
From the Main Menu, select 
OPTIONS > ADVANCED OPTIONS > 4–20 mA 
OUTPUTS > SELECT
.
Note: When the 4–20 mA outputs 
are disabled and not completely 
turned off, they will continue to 
output a steady 4 mA.
2.
 Enable the 4–20 mA outputs by pressing 
CHANGE CHOICE
 while in the 
4–20 mA output menu.
3.
When the display shows the outputs as enabled, press 
ACCEPT
4.
Choose either OUTPUT A or OUTPUT B. Use the 
UP
 and 
DOWN 
keys to 
highlight the choice, then press 
SELECT.
Table 16 4–20 mA Connections (J18)
Pin
Signal Description
Wire Color
A
Output 1 + (pos)
Yellow 
B
Output 1 - (neg)
Black
C
Output 2 + (pos)
Red
D
Output 2 - (neg)
Green