Graco 332230EN-F ユーザーズマニュアル

ページ / 32
Operation 
22
332230F
Operation
Charging Air Tank
1. Start engine and engage clutch. Compressor is now 
engaged.
2. If compressor is not needed for a job, move com-
pressor bypass switch (9) to horizontal ON position. 
Compressor is now exhausting air into atmosphere. 
3. Move compressor bypass switch (9) to vertical OFF 
position to charge air pressure tank. Air tank will 
continue to charge to 80 psi (5.5 bar, 55 MPa) then 
cycle between 60-80 psi (4.1-5.5 bar, 41-55 MPa).
4. See bead tank gauge (4) to read air tank pressure. 
Pressure from air tank is used to open bead valves 
at bead gun.
Setting Bead Hopper Pressure
The pressure regulator valve (5) controls pressure sent 
from the air tank to the bead tank. The regulator is set 
to 0 pressure from the factory. 
1. Before charging bead tank, confirm that bead tank 
lid is fully secured and beads have been loaded into 
tank.
2. To increase pressure, pull knob on pressure regula-
tor valve (5) out and turn counter-clockwise. Watch 
bead tank gauge (4) pressure and continue turning 
valve until desired pressure is met. 
3. See bead flow chart to find proper settings for your 
application. 
4. Various orifices can be used in gun to obtain 
different flow rates in conjunction with bead tank 
pressure. See Determining Bead Application 
Pressure Table
, page 24.
ti21074a
9
ti21081a
8
ti21073a
ti21082a
8
9
ti21079a
4
5
4
ti21083a