GM Gasoline V6 90 Degree ユーザーズマニュアル

ページ / 94
ENGINE APPLICATION MANUAL
GM Powertrain
Gasoline 4.3L V6 90 Degree
Revised: 08/15/2000
File: c:\data\manuales\v6-truck\am43v6#3.doc
Contact:Luis Nespolo - (248) 857-1558
Printed: 8/15/00
57
3.3.2 GMPT interface with Air Induction System
3.3.2.1 Air Requirement
Figure: 3.3.2.1-I 4.3L V6 90 Degree Engine Air Requirements
3.3.2.2 Air Flow Path
The air flow path in the vehicle at the air inlet of the air induction system shall not be
obstructed with vehicle components that will cause loss of pressure or flow disturbance.
All performance parameters specified in paragraph: 2.3.2.1 were measured with a maximum
air restriction of 1” of Hg.
As reference in table 3.3.2.1 - I, development power and torque data is shown to illustrate
the order of magnitude that may result as increasing the induction restriction.
RPM
L35
L35
Units
Truck
Marine
Application
Application
800
23.8
24.9
gr/sec
1200
37.8
39.3
gr/sec
1600
51.8
52.7
gr/sec
2000
65.8
67.4
gr/sec
2400
81.3
82.9
gr/sec
2800
97.7
99.0
gr/sec
3200
113.7
116.3
gr/sec
3600
128.8
130.5
gr/sec
4000
143.3
142.3
gr/sec
4400
154.7
154.0
gr/sec
4800
160.9
165.1
gr/sec
5200
163.7
175.0
gr/sec
Table 3.3.2.1 - I
4.3L V6
Development Peak Power and Torque Levels
Induction Restriction *
Induction
Torque
Power
Restriction
(Lb.-Ft)
(Hp)
1” Hg.
264
200
1.2” Hg.
262
198
1.4” Hg.
260
196
1.6” Hg.
258
194
Exhaust backpressure held at 11” Hg.