Excell Precision XR2625 ユーザーズマニュアル

ページ / 20
19 - ENG
A14687
Water 
leaking at 
pump
Water leaking 
at gun/
spray wand 
connection
No or low 
pressure 
(after period 
of normal 
use)
Spray wand not in low pressure.
See How to Use Spray Wand 
paragraph in the Operation 
Section.
Chemical screen not in cleaning 
solution.
Clean filter.
Chemical too thick.
Dilute chemical. Chemical should 
be the same consistency as water.
Pressure hose is too long
Lengthen water supply hose 
instead of high pressure hose.
Chemical build up in chemical 
injector.
Have parts cleaned or replaced
by AWSC.
Worn seal or packing
Have replaced by AWSC.
Worn or obstructed valves.
Have replaced by AWSC.
Worn unloader piston.
Have replaced by AWSC.
Check and replace.
Loose hose connection.
Loose connections.
Tighten.
Piston packings worn.
Have replaced by AWSC.
Worn or broken o-rings.
Have replaced by AWSC.
Pump head or tubes damaged 
from freezing.
Have replaced by AWSC.
Will not draw 
chemicals
Make sure end of chemical hose 
is fully submerged into cleaning 
solution.
Chemical filter clogged.
Worn or broken o-ring.
Tighten.
Nozzle obstructed.
See Nozzle Cleaning paragraph in 
the Maintenance section for the 
correct procedure.
Pump 
Pulsates
CAUSE
PROBLEM
CORRECTION
AWSC = Authorized Warranty Service Center