Epson V7 ユーザーズマニュアル

ページ / 344
3-36 
7. PLC2Way
4. Select the PLC model to be connected at 
the MJ port.  Click the [Setting] button.  
The [Type Setting] dialog is displayed.  
Select [PLC2Way].  The PLC manufacturer 
names who support PLC2Way 
communication are displayed.  Click [+].  
The available model names of the selected 
manufacturer are displayed.  Select the 
PLC model name and click [OK].  The 
message communication “Communication 
parameters are reset.  OK?” is displayed.
Click [Yes].
5. Set the parameters for the PLC to be connected at the MJ port.
[Baud Rate] (4800, 9600, 19200, 38400, 57600, 115000, 115 kbps)
Select the communication speed with the PLC connected at the MJ port.
[Parity] (None/Odd/Even)
Select the parity setting for communications with the PLC connected at the MJ port.
[Data Length] (7-bit/8-bit)
Select the data length for communications with the PLC connected at the MJ port.
[Stop Bit] (1-bit/2-bit)
Select the stop bit setting for communications with the PLC connected at the MJ 
port.
[Signal Level] (RS232C/RS485)
Select the signal level for communications with the PLC connected at the MJ port.
[Retrials]
Set the number of retrials to be attempted in the case that a communication error 
occurs.
[Time-out Time] (
×100 msec)
Select the receive time of the response from the PLC connected at the MJ port.  If 
no response is received within the specified time, a retrial is attempted.
[Send Delay Time] (
× msec)
Set a time delay in sending the response to the PLC after receipt of data from the 
PLC connected at the MJ port.