Installing the Chassis into a Rack
3-4 Enterasys Matrix N1 Chassis Setup
Installing the Chassis Directly to the Rack
To install the Enterasys Matrix N1 Chassis, proceed as follows:
1.
Lift the chassis into the rack and slide it all the way into the rack. Refer to 
2.
Use 4 screws (2 per side) provided with the equipment rack to secure the chassis to the rack, 
starting with the bottom holes and working toward the top of the chassis, as shown in 
.
Figure 3-1  Rack Mounting the Enterasys Matrix N1 Chassis
Attaching the Electrostatic Discharge Wrist Strap
The Electrostatic Discharge (ESD) wrist strap must be attached before handling the modules used 
in the Enterasys Matrix N1 Chassis. In addition, observe all precautions when handling these 
modules to prevent damage from electrostatic discharge.
Place the ESD wrist strap on your wrist and plug the other end into the grounding receptacle, at 
the top right corner of the chassis, shown in 
Caution: Read 
 before completing the following procedure to ensure that all installation 
guidelines are met.
Precaución: Antes de llevar a cabo el siguiente procedimiento, lea 
para y asegúrese 
de cumplir con todos los requisitos de instalación.
Warning: To help prevent personal injury, at least two people are required to lift the chassis into 
the rack. 
Advertencia: Para ayudar a prevenir alguna lesión personal, al menos dos personas son 
requeridas para levantar el chasis y meterlo al rack. 
Warnhinweis: Zum Schutz vor körperlichen Schäden, sollten sie mit min. zwei Personen das 
Chassis in das Rack heben. 
Rails of 19-inch rack
2 Mounting screws (supplied by user)
Note:  The Enterasys Matrix N1 Chassis must not exceed the 2U high rackmount standard and 
must comply with the requirements for mounting in a 19-inch (48.26-centimeter) rack. 
2
1
1
2
FAN
STATUS
PS1
STATUS
PS2
STATUS
N1
GROUND
STRAP
7C111