  4.6  Checking and Changing Rotation of RSIB 350, 400, and 500
 
 
To check the rotation of the impeller, it is necessary to be able to  
 
 
 
see the impeller or the rotation of the cooling vanes at the end of the   
 
 
motor housing.
 
 
Standing in front of the fan with the motor pointing towards you, the    
 
 
rotation must be clockwise.  This is indicated by an arrow on the  
 
 
 
motor end cover.  There are holes in the end cover that allow you    
to see the cooling vanes, but it is difficult to see the rotation unless the
 
 
fan is running very slowly.
 
 
For a more precise determination, you may also see down inside the  
 
 
fan housing, as shown in Fig.13. The arrow shown  
 
 
 
 
(not actually inside fan housing) shows the proper rotation.
 
 
It is possible for the fan to operate with improper rotation.  However,   
 
 
although some performance can be seen the fan will probably  
 
 
 
only provide 25-30% of full capacity.  Improper rotation wears on the   
 
 
motor, and causes various electrical faults at the Variable Frequency   
 
 
Drive.
 
 
Fan rotation can be changed by swapping the two phase wires as    
 
 
shown on the wiring diagram in Fig.14.   
Fig. 13
Fig. 14