Emerson Liebert PSA Line-Interactive UPS 500-1500VA ユーザーズマニュアル

ページ / 120
Operating System Details
101
Liebert
®
 MultiLink
®
A.6 H
EWLETT
P
ACKARD®
HP-UX
A.6.1 Platform-Specific Requirements
In addition to the general requirements listed in 3.0 - What is Required to Use Liebert 
MultiLink?, prospective Liebert MultiLink users must also have these minimal requirements:
• HP-UX 11 or 11i
• Appropriate patches applied to operating system. For patches required to run Java 1.4.2, see:
• Common Desktop Environment (X Window System)
• TCP/IP network protocol
• 100 MB of free disk space on the partition where Liebert MultiLink will be installed (during 
installation, the /tmp directory must have 200 MB free)
• A mouse or other pointing device
• 512 MB of RAM
• A minimum of 90 threads per process. This is the kernel parameter 
max_thread_proc
, which can 
be viewed or modified using SAM.
• HP recommends mid-range N class and low-end L-class systems and PA-8500-based workstations 
to obtain optimal performance when running Java applications. The recommended minimum 
system for running Java applications is a PA-RISC 2.0 system or a PA-RISC 1.1 system with a 
floating-point coprocessor. For information on setting important system parameters required for 
correct execution of Java programs, go to 
A.6.2 Installation Notes
Pre-Installation Checklist
Comply with the following requirements, then return to 5.1 - Before Installing Liebert MultiLink.
1. During installation you must be logged in as “root.”
2. If using a serial port connection to the UPS, use the SAM utility to disable getty or uugetty at 
system startup from monitoring the port where you are connecting the UPS. Optionally, you can 
delete or comment the following line (or similar) from the 
/etc/inittab
 file:
ttp1:234:respawn:/usr/sbin/getty –h tty0p1 9600
3. If you are using an SNMP card, check for SNMP daemons. Execute the command
ps -ef | grep -i snmp
. If the processes snmpd or snmpdm are running, they must be disabled 
before you can install Liebert MultiLink.
If you are not using an SNMP hardware card with your UPS, Liebert MultiLink can use its 
default port settings of 3029/3027, and there is no need to disable the SNMP daemons.
4. Make sure the Liebert MultiLink distribution file has execute permission (
chmod +x <file>
), 
then execute it.
Alternate to /tmp during installation
If you do not have enough disk space in the /tmp partition to meet the requirement specified in 
A.6.1 - Platform-Specific Requirements, you may specify an alternate location when starting the 
installation. For example, to use /home/tmp, start the install with the following command:
./ML_36_003_HP-UX.bin /home/tmp
Serial Port Selection
The preconfigured serial ports are 
/dev/tty0p0
 and 
/dev/tty1p0
. You may select one of these or 
enter another as appropriate.
Post-Installation Notes
The Liebert MultiLink installation program places the script 
LiebertM
 in the 
/sbin/init.d
 directory. 
It also creates K300LiebertM and S900LiebertM links in the 
/sbin/rc1.d
 and 
/sbin/rc2.d
 
directories.