iRMC
S2/S3
Configuring and using the serial interface of the iRMC S2/S3
Flow Control
None
Exiting the UEFI setup utility
Ê
Save your settings and exit the UEFI setup utility.
Ê
Continue with
.
3.3.3
Using the Remote Manager (Serial) interface
If you connect a computer over a null modem cable and start a terminal program
(VT100+) on this computer, you can access the Remote Manager (Serial)
terminal program. The Remote Manager (Serial) interface is identical to the
Remote Manager interface (see
(VT100+) on this computer, you can access the Remote Manager (Serial)
terminal program. The Remote Manager (Serial) interface is identical to the
Remote Manager interface (see
).
Prerequisites
On the managed server:
The
Serial Multiplexer
BIOS setting must be configured on the
iRMC
(see
).
Terminal program (VT100+):
Configure the following port settings for the terminal program:
Bits per second
Set the value to
9600
.
Data bits
Set the value to
8
.
Parity
Set the value to
None
.
Stop bits
Set the value to
1
.
Flow Control
Set the value to
None
.