operating voltage The amplifier is set at the factory (internally) for 100V, 120V, 220V, 230V, or 
240V AC mains operation, as appropriate for the country in which it is to be 
sold (230V only in European Union countries, in compliance with CE regulations)
The voltage setting may not be changed by the user or dealer.
Make sure that the label on the rear panel of your power amplifier indicates 
the correct AC operating voltage for your location. Attempting to operate your 
power amplifier at an incorrect voltage may damage the unit.
 
Warning: 
The voltage setting of your power amplifier may not be 
changed by the user. There are no user-serviceable parts 
within the unit. Please refer any problems to an authorized 
Classé service center.
If the AC mains voltage indicated on your power amplifier is incorrect, please 
contact your local, authorized Classé dealer or distributor.
The amplifier can easily be powered by a normal 15 or 20-ampere AC mains 
line. If other devices are also powered from the same AC line, their additional 
power consumption should be taken into account.
The amplifier includes protection circuitry that will prevent the amplifier from 
operating at dangerously high or low voltages. 
•  At startup: the AC mains voltage must be within a range of 
approximately -15% to +10% of its nominal value at startup, or 
the amplifier will not turn on. For example, a 120V unit requires 
the AC mains to be between approximately 95V–135V in order to 
turn on.
•  Over-voltage during operation: if the AC mains voltage surges 
by roughly 10% or more during operation, the amplifier will enter 
protection mode and shut down. The Standby LED will flash to 
indicate the protection mode has been engaged.
•  Under-voltage during operation: if the AC mains voltage sags by 
15% or more, the amplifier will continue to play (since this does 
not present a particular danger to the amplifier), but note that 
it may not be able to achieve its usual standard of performance 
under these compromised conditions. The Standby LED will flash 
to indicate the condition.