Carrier Access Network Device Axxius 800 ユーザーズマニュアル

ページ / 568
Axxius 800 - Release 2.2
4-7
 Configuration
Basic System Setup
Set Up a DS3
Use the following commands to set up a DS3. See the set (ds3) command for more 
details.
Command
Description
set {ds3-addr} up
Activate the port. 
set {ds3-addr} id 
{"id-name"}
Set the DS3 ID. 
set {ds3-addr} clock
{loop|normal}
Set the transmit clock source. 
set {ds3-addr} berthreshold
{value}
Set the Bit Error Rate protection switchover 
threshold. 
set {ds3-addr} dejitter
{off|on}
Set the De-jitter buffer on or off. 
set {ds3-addr} equipment id
{"string"}
Set the DS3 equipment PMDL ID string. 
set {ds3-addr} facility id 
{"string"}
Set the DS3 facility PMDL ID string. 
set {ds3-addr} frame 
{"string"}
Set the DS3 frame PMDL ID string. 
set {ds3-addr} framing 
{cbit|m23}
Set the framing option for the DS3. 
set {ds3-addr} location id 
{"string"}
Set the DS3 location PMDL ID string. 
set {ds3-addr} portnum 
{"string"}
Set the DS3 port number PMDL string.
set {ds3-addr} gennum 
{"string"}
Set the DS3 generation number PMDL 
string.
set {ds3-addr} loopdetect 
{off|on}
Set the detection/reaction to CSU 
loopcodes.